§ 3-13. Accessory structures.
(a) In general.
Accessory structures shall be limited to no more than 300 square feet in total floor area.
(b) Requirements.
Accessory structures:
(1) shall comply with the elevation requirements and other requirements of § 3-14 {"Enclosures below the first floor or flood-protection elevation"} of this subtitle; or
(2) shall:
(i) be useable only for parking of vehicles or limited storage;
(ii) be constructed with flood damage-resistant materials below the flood-protection elevation;
(iii) be constructed and placed to offer the minimum resistance to the flow of floodwaters;
(iv) be anchored to prevent flotation;
(v) have electrical service and mechanical equipment elevated to or above the flood-protection elevation; and
(vi) have flood openings that meet the criteria described in § 1-3(a) {"Definitions: Floodproofing"} of this Division I.